NiO HSE06

From VASP Wiki
Revision as of 15:28, 24 August 2016 by Xavier (talk | contribs) (Created page with "Description: Hybrid functional calculation using the HSE For other hybrid functionals ---- *INCAR <pre> NiO HSE06 AFM SYSTEM = "NiO" Elect...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Description: Hybrid functional calculation using the HSE For other hybrid functionals


  • INCAR
NiO HSE06 AFM
  SYSTEM   = "NiO"

Electronic minimization
  ENCUT    = 300
  EDIFF    = 1E-4
  LORBIT   = 11
  LREAL = .False.
  ISTART   = 0
  NELMIN = 6

DOS
  ISMEAR   = -5

Magnetism
  ISPIN    = 2
  MAGMOM   = 2.0 -2.0 2*0 

Mixer
  AMIX     = 0.2
  BMIX     = 0.00001
  AMIX_MAG = 0.8
  BMIX_MAG = 0.00001 

Hybrid functional
  LHFCALC  = .TRUE.
  HFSCREEN = 0.2 
  • KPOINTS
k-points
 0
gamma
 4  4  4 
 0  0  0
  • POSCAR
NiO
 4.17
 1.0 0.5 0.5
 0.5 1.0 0.5
 0.5 0.5 1.0
 2 2
Cartesian
 0.0 0.0 0.0
 1.0 1.0 1.0
 0.5 0.5 0.5
 1.5 1.5 1.5

Download

Ni111clean_400eV.tgz


To the list of examples or to the main page