Nucleophile Substitution CH3Cl - Standard MD: Difference between revisions

From VASP Wiki
No edit summary
Line 57: Line 57:


=== {{TAG|ICONST}} ===
=== {{TAG|ICONST}} ===
For this example an {{TAG|ICONST}} file is used  
For this example an {{TAG|ICONST}} file is used which looks like:
  R 1 5 0
  R 1 5 0
  R 1 6 0
  R 1 6 0

Revision as of 08:01, 11 June 2019

Task

The main task of this example is to model a nucleophile substitution of CH3Cl by Cl-.

Input

POSCAR

CH3Cl                                         
   1.00000000000000     
    12.0000000000000000    0.0000000000000000    0.0000000000000000
     0.0000000000000000   12.0000000000000000    0.0000000000000000
     0.0000000000000000    0.0000000000000000   12.0000000000000000 
C H Cl
   1   3   2
cart
         5.91331371  7.11364924  5.78037960
         5.81982231  8.15982106  5.46969017
         4.92222130  6.65954232  5.88978969
         6.47810398  7.03808479  6.71586385
         4.32824726  8.75151396  7.80743202
         6.84157897  6.18713289  4.46842049

A sufficiently large cell is chosen to minimize the interactions between neighbouring cells and hence to simulate an isolated molecular reaction.

KPOINTS

Automatic
 0
Gamma
 1  1  1
 0. 0. 0.

For isolated atoms and molecules interactions between periodic images are negligible (in sufficiently large cells) hence no Brillouin zone sampling is necessary.

INCAR

PREC=Low
EDIFF=1e-6
LWAVE=.FALSE.
LCHARG=.FALSE.
NELECT=22
NELMIN=4
LREAL=.FALSE.
ALGO=VeryFast
ISMEAR=-1
SIGMA=0.0258

############################# MD setting #####################################
IBRION=0                                           # MD simulation
NSW=1000                                           # number of steps
POTIM=1                                            # integration step
TEBEG=300                                          # simulation temperature
MDALGO=11                                          # metaDynamics with Andersen thermostat
ANDERSEN_PROB=0.10                                 # collision probability
##############################################################################
  • Molecular dynamics are switched on by the tag IBRION=0.
  • The metadynamics tag MDALGO=11 is only used to monitor the two C-Cl distances defined in the ICONST file.
  • Simulations are carried out in the NVT ensemble at approximately room temperature (TEBEG=300) and the Anderson thermostat is used for the temperature control. The strength of the coupling is controlled by the collision probability {TAGBL|ANDERSEN_PROB}}=0.10.
  • The accuracy of this calculation is kept low (PREC=Low and ALGO=VeryFast), which is completely sufficient for this tutorial. For more quantitative results this tags should be changed (of course at the cost of higher computational demand).

ICONST

For this example an ICONST file is used which looks like:

R 1 5 0
R 1 6 0
S 1 -1 7
  • First line: This line selects the interatomic distance (R) between the first (C) and the fifth atom (Cl) in the POSCAR file. The 0 at the fourth entry would usually specify that the distances are constrained but if the coordinates are used later for special coordinates the constraining is not applied (for further information see ICONST).
  • Second line: Same as the first line but interatomic distance between the first (C) and the sixth atom (Cl) in the POSCAR file is selected.
  • Third line: This line selects a linear combination (option S) of the first two coordinates where the second and fourth column specify the coefficients of the coordinates. The setting of 1 and -1 corresponds to the difference between both. The 7 at the fourth entry specifies that difference between these two distances is monitored but no constraints are applied.