ML CTIFOR: Difference between revisions
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{TAGDEF|ML_FF_CTIFOR|[real]|<math> 10^{-16}</math>}} | {{TAGDEF|ML_FF_CTIFOR|[real]|<math> 10^{-16}</math>}} | ||
Description: | Description: This flag sets the threshold for the Bayesian error estimation on the force in the machine learning force field methods. | ||
---- | ---- | ||
Revision as of 12:15, 27 May 2019
ML_FF_CTIFOR = [real]
Default: ML_FF_CTIFOR =
Description: This flag sets the threshold for the Bayesian error estimation on the force in the machine learning force field methods.
Within the learning step if a newly considered structure gives a spilling factor larger than ML_FF_CTIFOR, the sampling is stopped and a new force field is generated. This flag is only used if ML_FF_IERR=2 or 3. The unit of ML_FF_CTIFOR is in eV/Angstrom.
Related Tags and Sections
ML_FF_LMLFF, ML_FF_IERR, ML_FF_CSF