CUTOFF SIGMA: Difference between revisions
No edit summary |
Tag: Undo |
||
Line 3: | Line 3: | ||
{{DEF|CUTOFF_SIGMA|0.1|}} | {{DEF|CUTOFF_SIGMA|0.1|}} | ||
Description: {{TAG|CUTOFF_SIGMA}} specifies | Description: {{TAG|CUTOFF_SIGMA}} specifies a broadening <math>\sigma</math> in units of eV in for the cutoff function specified by {{TAG|CUTOFF_TYPE}}. | ||
---- | ---- |
Revision as of 09:03, 20 July 2022
CUTOFF_SIGMA = [real]
Default: CUTOFF_SIGMA | = 0.1 |
Description: CUTOFF_SIGMA specifies a broadening in units of eV in for the cutoff function specified by CUTOFF_TYPE.
Corresponds to a broadening of the cutoff function to be used in the one-shot method to obtain Wannier functions. The meaning depends on the CUTOFF_TYPE tag.
Related tags and articles
CUTOFF_TYPE, CUTOFF_MU, LSCDM, LOCPROJ