WC: Difference between revisions
(Created page with '{{TAGDEF|WC|[real]|1000.}} Description: {{TAG|WC}} specifies the weight factor for each step in Broyden mixing scheme ({{TAG|IMIX}}=4). ---- *{{TAG|WC}}>0 :Set all weights ident…') |
No edit summary |
||
Line 25: | Line 25: | ||
{{TAG|AMIN}}, | {{TAG|AMIN}}, | ||
{{TAG|MIXPRE}} | {{TAG|MIXPRE}} | ||
{{sc|WC|Examples|Examples that use this tag}} | |||
---- | ---- | ||
[[The_VASP_Manual|Contents]] | [[The_VASP_Manual|Contents]] | ||
[[Category:INCAR]][[Category:Mixing]] | [[Category:INCAR]][[Category:Mixing]] |
Revision as of 13:16, 20 March 2017
WC = [real]
Default: WC = 1000.
Description: WC specifies the weight factor for each step in Broyden mixing scheme (IMIX=4).
- WC>0
- Set all weights identical to WC (resulting in Pulay's mixing method), up to now Pulay's scheme was always superior to Broyden's 2nd method.
- WC=0
- Switch to Broyden's 2nd method, i.e., set the weight for the last step equal to 1000 and all other weights equal to 0.
- WC<0 (implemented for test purposes: not recommended)
- Try some automatic setting of the weights according to:
- in order to set small weights for the first steps and increasing weights for the last steps.
Related Tags and Sections
IMIX, INIMIX, MAXMIX, AMIX, BMIX, AMIX_MAG, BMIX_MAG, AMIN, MIXPRE