ENCUTGWSOFT: Difference between revisions

From VASP Wiki
No edit summary
No edit summary
Line 11: Line 11:
\qquad \mbox{for} \quad  \frac{\hbar^2 |\bf G|^2 }{2 m_e} >  {{TAG|ENCUTGWSOFT}}</math>  
\qquad \mbox{for} \quad  \frac{\hbar^2 |\bf G|^2 }{2 m_e} >  {{TAG|ENCUTGWSOFT}}</math>  


<math>v_{\bf G} = \frac{4 \pi e^2} {| \bf G|^2}</math>  
<math>v_{\bf G} = \frac{4 \pi e^2} {{{|}} \bf G{{|}}^2}</math>  
== Related Tags and Sections ==
== Related Tags and Sections ==
{{TAG|PRECFOCK}},
{{TAG|PRECFOCK}},

Revision as of 17:35, 15 January 2017

ENCUTGWSOFT = [real] (energy cutoff for response function) 

Default: ENCUTGWSOFT = ENCUTGW for ALGO=ACFDT
= ENCUTGW else


The flag allows to truncate the Coulomb kernel slowly between the energy specified by ENCUTGWSOFT and ENCUTGW. This usually leads to much smoother energy-volume curves in AC-FDT and MP2 calculations. The modified Coulomb kernel is in this case:

Related Tags and Sections

PRECFOCK, ENCUT, ENCUTGW, GW calculations


Contents