Three types of DFT+U approaches are available in VASP. These are the following: | |||
*{{TAG|LDAUTYPE}}=1: The rotationally invariant DFT+U introduced by Liechtenstein ''et al.''{{cite|liechtenstein:prb:95}} | *{{TAG|LDAUTYPE}}=1: The rotationally invariant DFT+U introduced by Liechtenstein ''et al.''{{cite|liechtenstein:prb:95}} |
Revision as of 19:46, 6 April 2022
LDAUTYPE = 1 | 2 | 4
Default: LDAUTYPE = 2
Description: LDAUTYPE specifies which type of DFT+U approach will be used.
Three types of DFT+U approaches are available in VASP. These are the following:
- This particular flavour of DFT+U is of the form
- and is determined by the PAW on-site occupancies
- and the (unscreened) on-site electron-electron interaction
- where are real spherical harmonics of angular momentum =LDAUL.
- The unscreened electron-electron interaction can be written in terms of the Slater integrals , , , and (f-electrons). Using values for the Slater integrals calculated from atomic orbitals, however, would lead to a large overestimation of the true e-e interaction, since in solids the Coulomb interaction is screened (especially ).
- In practice these integrals are often treated as parameters, i.e., adjusted to reach agreement with experiment for a property like the equilibrium volume, the magnetic moment or the band gap. They are normally specified in terms of the effective on-site Coulomb- and exchange parameters, and (LDAUU and LDAUJ, respectively). and can also be extracted from constrained-DFT calculations.
- These translate into values for the Slater integrals in the following way (as implemented in VASP at the moment):
- - -
- The essence of the DFT+U method consists of the assumption that one may now write the total energy as:
- where the Hartree-Fock like interaction replaces the semilocal on site due to the fact that one subtracts a double counting energy , which supposedly equals the on-site semilocal contribution to the total energy,
- LDAUTYPE=2: The simplified (rotationally invariant) approach to the DFT+U, introduced by Dudarev et al.[2]
- This flavour of DFT+U is of the following form:
- This can be understood as adding a penalty functional to the semilocal total energy expression that forces the on-site occupancy matrix in the direction of idempotency,
- .
- Real matrices are only idempotent when their eigenvalues are either 1 or 0, which for an occupancy matrix translates to either fully occupied or fully unoccupied levels.
- Note: in Dudarev's approach the parameters and do not enter seperately, only the difference is meaningful.
- In the LDA+U case the double counting energy is given by,
Warning: it is important to be aware of the fact that when using the DFT+U, in general the total energy will depend on the parameters and (LDAUU and LDAUJ, respectively). It is therefore not meaningful to compare the total energies resulting from calculations with different and/or , or and in case of Dudarev's approach (LDAUTYPE=2).
Note on bandstructure calculation: the CHGCAR file contains only information up to angular momentum quantum number =LMAXMIX for the on-site PAW occupancy matrices. When the CHGCAR file is read and kept fixed in the course of the calculations (ICHARG=11), the results will be necessarily not identical to a selfconsistent run. The deviations are often large for DFT+U calculations. For the calculation of band structures within the DFT+U approach, it is hence strictly required to increase LMAXMIX to 4 ( elements) and 6 ( elements).
Related Tags and Sections
LDAU, LDAUL, LDAUU, LDAUJ, LDAUPRINT, LMAXMIX