Biased molecular dynamics: Difference between revisions
Line 52: | Line 52: | ||
* For a biased molecular dynamics run with Nose-Hoover thermostat, one has to: | * For a biased molecular dynamics run with Nose-Hoover thermostat, one has to: | ||
#Set the standard MD-related tags: {{TAG|IBRION}}=0, {{TAG|TEBEG}}, {{TAG|POTIM}}, and {{TAG|NSW}} | #Set the standard MD-related tags: {{TAG|IBRION}}=0, {{TAG|TEBEG}}, {{TAG|POTIM}}, and {{TAG|NSW}} | ||
#Set {{TAG|MDALGO}}=21, and choose an appropriate setting for {{TAG|SMASS}} | #Set {{TAG|MDALGO}}=2 ({{TAG|MDALGO}}=21 in VASP 5.x), and choose an appropriate setting for {{TAG|SMASS}} | ||
#In order to avoid updating of the bias potential, set {{TAG|HILLS_BIN}}={{TAG|NSW}} | #In order to avoid updating of the bias potential, set {{TAG|HILLS_BIN}}={{TAG|NSW}} | ||
#Define collective variables in the {{FILE|ICONST}}-file, and set the <tt>STATUS</tt> parameter for the collective variables to 5 | #Define collective variables in the {{FILE|ICONST}}-file, and set the <tt>STATUS</tt> parameter for the collective variables to 5 |
Revision as of 17:51, 30 January 2020
The probability density for a geometric parameter ξ of the system driven by a Hamiltonian:
with T(p), and V(q) being kinetic, and potential energies, respectively, can be written as:
The term stands for a thermal average of quantity X evaluated for the system driven by the Hamiltonian H.
If the system is modified by adding a bias potential acting only on a selected internal parameter of the system ξ=ξ(q), the Hamiltonian takes a form:
and the probability density of ξ in the biased ensemble is:
It can be shown that the biased and unbiased averages are related via a simple formula:
More generally, an observable :
can be expressed in terms of thermal averages within the biased ensemble:
Simulation methods such as umbrella sampling[1] use a bias potential to enhance sampling of ξ in regions with low P(ξi) such as transition regions of chemical reactions. The correct distributions are recovered afterwards using the equation for above.
A more detailed description of the method can be found in Ref.[2]. Biased molecular dynamics can be used also to introduce soft geometric constraints in which the controlled geometric parameter is not strictly constant, instead it oscillates in a narrow interval of values.
Andersen thermostat
- For a biased molecular dynamics run with Andersen thermostat, one has to:
- Set the standard MD-related tags: IBRION=0, TEBEG, POTIM, and NSW
- Set MDALGO=1 (MDALGO=11 in VASP 5.x), and choose an appropriate setting for ANDERSEN_PROB
- In order to avoid updating of the bias potential, set HILLS_BIN=NSW
- Define collective variables in the ICONST-file, and set the STATUS parameter for the collective variables to 5
- Define the bias potential in the PENALTYPOT-file
Nose-Hoover thermostat
- For a biased molecular dynamics run with Nose-Hoover thermostat, one has to:
- Set the standard MD-related tags: IBRION=0, TEBEG, POTIM, and NSW
- Set MDALGO=2 (MDALGO=21 in VASP 5.x), and choose an appropriate setting for SMASS
- In order to avoid updating of the bias potential, set HILLS_BIN=NSW
- Define collective variables in the ICONST-file, and set the STATUS parameter for the collective variables to 5
- Define the bias potential in the PENALTYPOT-file
The values of all collective variables for each MD step are listed in the REPORT-file, check the lines after the string Metadynamics.
References
- ↑ G. M. Torrie and J. P. Valleau, J. Comp. Phys. 23, 187 (1977).
- ↑ D. Frenkel and B. Smit, Understanding molecular simulations: from algorithms to applications, Academic Press: San Diego, 2002.