Bethe-Salpeter-equations calculations: Difference between revisions

From VASP Wiki
No edit summary
 
(67 intermediate revisions by 6 users not shown)
Line 1: Line 1:
VASP offers a powerful module for solving the Bethe-Salpeter (BSE) equation{{cite|albrecht:prl:98}}{{cite|rohlfing:prl:98}}. The BSE can be used for obtaining the frequency-dependent dielectric function with the excitonic effects and can be based on the ground-state electronic structure in the DFT, hybrid-functional or ''GW'' approximations. 
__TOC__
__TOC__


VASP offers a powerful and highly predictive module for Bethe-Salpeter<ref name="albrecht1998"/><ref name="rohlfing1998"/> BSE and time-dependent Hartree-Fock calculations (TDHF). It can be used to calculate the response function including excitonic effects on top of GW or hybrid functional calculations. We will first introduce a typical calculation and then report on the required flags in more detail.
== Solving Bethe-Salpeter equation ==
To take into account the excitonic effects or the electron-hole interaction, one has to use approximations beyond the independent-particle (IP) and the random-phase approximations ([[RPA/ACFDT: Correlation energy in the Random Phase Approximation|RPA]]). In VASP, it is done via the algorithm selected by {{TAG|ALGO}} = BSE. These essentially solves the same equations (Casida/Bethe-Salpeter) but differ in the way the screening of the Coulomb potential is treated. The TDHF approach uses the exact-correlation kernel <math>f_{\rm xc}</math>, whereas BSE requires the <math>W(\omega \to 0)</math> from a preceding ''GW '' calculation. Thus, in order to perform  TDHF or BSE calculations, one has to provide the ground-state orbitals ({{FILE|WAVECAR}}) and the derivatives of the orbitals with respect to <math>k</math> ({{FILE|WAVEDER}}). In addition, the BSE calculation requires files storing the screened Coulomb kernel produced in a ''GW'' calculation, i.e., {{FILE|Wxxxx.tmp}}.
 
In summary, both TDHF and BSE approaches require a preceding ground-state calculation, however, the TDHF does not need the preceding ''GW'' and can be performed with the DFT or hybrid-functional orbitals and energies.
 
== Bethe-Salpeter equation calculation ==
The BSE calculations require a preceding ''GW'' step to determine the screened Coulomb kernel <math>W_{GG'}(q,\omega \to 0 )</math>. The details on ''GW'' calculations can be found in the practical guide to [[Practical guide to GW calculations|''GW'' ]]  calculations. Here, we note that during the ''GW'' calculation, VASP writes this kernel into the following files
 
W0001.tmp, W0002.tmp, ..., W{NKPTS}.tmp
 
and
 
WFULL0001.tmp, WFULL0002.tmp, ..., WFULL{NKPTS}.tmp.
 
The files {{FILE|Wxxxx.tmp}} store only the diagonal terms of the kernel and are fairly small, whereas the files {{TAG|WFULLxxxx.tmp}} store the full matrix. It is important to make sure in the ''GW'' step that the flag {{TAG|LWAVE}} = .TRUE. is set, so that the {{FILE|WAVECAR}} stores the one-electron ''GW'' energies and the one-electron orbitals, if the ''GW'' calculation is self-consistent.
 
For the self-consistent ''GW'' calculations the following flags should be added
 
{{TAG|LOPTICS}}  = .TRUE.
{{TAG|LPEAD}}    = .TRUE.


To calculate spectra beyond the independent particle approximation and beyond the random phase approximation (RPA) the flag {{TAG|ALGO}} needs to be set to {{TAG|ALGO}}=''TDHF'' or {{TAG|ALGO}}=''BSE''. Internally {{TAG|ALGO}}=''TDHF'' and {{TAG|ALGO}}=''BSE'' use identical routines  to calculate  the dielectric function, however, the electron-hole ladder diagrams are either approximated by the screened exchange or by  <math>W(\omega\to 0)</math> calculated in a preceding GW calculations.
in order to update the {{FILE|WAVEDER}} using finite differences ({{TAG|LPEAD}} = .TRUE.). The type of ''GW'' calculation is selected with the {{TAG|ALGO}} tag, which is discussed in great detail in  the practical guide to ''GW'' calculations.


The first case, {{TAG|ALGO}}=''TDHF'' is simpler. The calculations need to be done in two steps. The first step is a standard DFT or hybrid functional calculation, where the number of bands is increased to include the relevant conduction bands in the calculation:
Once the ''GW'' step is completed, the BSE calculation can be performed using the following setup


  {{TAGBL|System}} = Si
  {{TAG|SYSTEM}}   = Si
  {{TAGBL|NBANDS}} = 16 ! or any larger desired value
  {{TAG|NBANDS}}   = same as in GW calculation
  {{TAGBL|ISMEAR}} = 0 ; {{TAGBL|SIGMA}} = 0.05
  {{TAG|ISMEAR}}   = 0
  {{TAGBL|ALGO}} = D
{{TAG|SIGMA}}     = 0.05
  {{TAGBL|LHFCALC}} = .TRUE. ; {{TAGBL|AEXX}} = 0.3 ; {{TAGBL|HFSCREEN}} = 0.2
  {{TAG|ALGO}}     = BSE
  {{TAGBL|LOPTICS}} = .TRUE. ! can also be done in an additional intermediate step
  {{TAG|NBANDSO}}   = 4      ! determines how many occupied bands are used
{{TAG|NBANDSV}}   = 8      ! determines how many unoccupied (virtual) bands are used
  {{TAG|OMEGAMAX}} = desired_maximum_excitation_energy


In the second step, the dielectric function is evaluated by solving the Cassida equation
Considering that quasiparticle energies in ''GW'' converge very slowly with the number of unoccupied bands and require large {{TAG|NBANDS}}, the number of bands included in the BSE calculation should be restricted explicitly by setting the occupied and unoccupied bands ({{TAG|NBANDSO}} and {{TAG|NBANDSV}}) included in the BSE Hamiltonian.


{{TAGBL|System}}  = Si
VASP tries to use sensible defaults, but it is highly recommended to check the {{FILE|OUTCAR}} file and make sure that the right bands are included. The tag {{TAG|OMEGAMAX}} specifies the maximum excitation energy of included electron-hole pairs and the pairs with the one-electron energy difference beyond this limit are not included in the BSE HamiltonianHint: The convergence with respect to {{TAG|NBANDSV}} and {{TAG|OMEGAMAX}} should be thoroughly checked as the real part of the dielectric function, as well as the correlation energy, is usually very sensitive to these values, whereas the imaginary part of the dielectric function converges quickly.
{{TAGBL|NBANDS}} = 16
{{TAGBL|ISMEAR}} = 0 ; {{TAGBL|SIGMA}} = 0.05
  {{TAGBL|ALGO}} = TDHF
{{TAGBL|LHFCALC}} = .TRUE. ; {{TAGBL|AEXX}} = 0.3 ; {{TAGBL|HFSCREEN}} = 0.2


In this case the exchange kernel, as selected in the fifth line, should be identical to the previous groundstate calculations. The present implementation can be used for spin-polarized as well as non-collinear (spin-orbit) cases. There is, however, one caveat. The local exchange-correlation kernel is not exactly included and approximated by the density-density part only. This makes predictions for spin polarized systems less accurate then for non-spin polarized systems.
At the beginning of the BSE calculation, VASP will try to read the {{FILE|WFULLxxxx.tmp}} files and if these files are not found, VASP will read the {{FILE|Wxxxx.tmp}} files. For small isotropic bulk systems, the diagonal approximation of the dielectric screening may be sufficient and yields results very similar to the calculation with the full dielectric tensor {{TAG|WFULLxxxx.tmp}}. Nevertheless, for molecules and atoms as well as surfaces, the full-screened Coulomb kernel is strictly required.


The calculation of the dielectric function is also possible after GW type calculations (GW+BSE). Make certain that in the preceding GW calculations, the flag  {{TAG|LWAVE}}=''.TRUE.'' is set, so that the {{TAG|WAVECAR}} file is updated to store the updated one-electron GW energies and possibly the updated one-electron orbitals as determined in the  scGW calculations. The BSE calculation is initiated using:
Both TDHF and BSE approaches write the calculated frequency-dependent dielectric function as well as the excitonic energies in the {{TAG|vasprun.xml}} file.


{{TAGBL|System}}  = Si
== Model BSE (mBSE) ==
{{TAGBL|NBANDS}} = same as in GW calculation
BSE calculations can be performed using a model dielectric function{{cite|bokdam:scr:2016}}{{cite|tal:prr:2020}}. In this approach the calculation of the screened Coulomb potential is not required. Instead, the model dielectric function can be used to describe the screening of the Coulomb potential by setting the tag {{TAG|LMODELHF}} with parameters {{TAG|AEXX}} and {{TAG|HFSCREEN}}.
{{TAGBL|ISMEAR}} = 0 ; {{TAGBL|SIGMA}} = 0.05
{{TAGBL|ALGO}} = BSE
{{TAGBL|NBANDSO}} = 4 ; {{TAGBL|NBANDSV}} = 8 # determines how many occupied and virtual


It is strongly recommended to set the flags {{TAG|NBANDSO}} and {{TAG|NBANDSV}}: in GW calculations
Model BSE calculation can be performed the following steps:  
usually a very large number of bands is included. For the BSE, it is however desirable to restrict the number
# ground-state calculation
of bands when solving the Cassida/BSE equations. {{TAG|NBANDSO}} controls how many occupied bands (below the Fermi-level) are included,
# GW calculation (optional in model BSE calculation)
whereas {{TAG|NBANDSV}} determines the number of virtual (unoccupied) bands included above the Fermi-level. VASP tries to
# optical absorption calculation via model BSE
use sensible defaults, but it is always wise to check the {{TAG|OUTCAR}} file whether these agree with what the user desires.
The difference between For  {{TAG|ALGO}}=''TDHF'' and  {{TAG|ALGO}}=''BSE'', is that for  {{TAG|ALGO}}=''BSE'' the particle-hole ladders are approximated
by the <math>W(\omega \to 0)</math> calculated in the preceding GW calculations. To this end, vasp writes the following files during the GW step


W0001.tmp  W0002.tmp  W0003.tmp
For example, an optical absorption calculation of bulk Si can be performed using a model dielectric function as described in Ref. {{cite|tal:prr:2020}}.


and
{{TAG|SYSTEM}}    = Si
{{TAG|ISMEAR}}    = 0
{{TAG|SIGMA}}    = 0.05
{{TAG|NBANDS}}    = 16      ! or any larger desired value
{{TAG|ALGO}}      = D      ! Damped algorithm often required for HF type calculations, {{TAG|ALGO}} = Normal might work as well
{{TAG|LHFCALC}}  = .TRUE.
{{TAG|LMODELHF}}  = .TRUE.
{{TAG|AEXX}}      = 0.083
{{TAG|HFSCREEN}}  = 1.22
{{TAG|LOPTICS}}  = .TRUE.  ! can also be done in an additional intermediate step


WFULL0001.tmp  WFULL0002.tmp  WFULL0003.tmp
In the second step, the dielectric function is evaluated by solving the Casida equation


The files {{TAG|W000}}?.tmp store only the diagonal elements of the screened exchange <math>W</math>, and are therefore fairly small, whereas the files {{TAG|WFULL000}}?.tmp store the full matrix (the integer corresponds to the k-point index). During the BSE calculations, VASP will first try to read the {{TAG|WFULL000}}?.tmp files and then, if these are missing, the {{TAG|W000}}?.tmp files. For small isotropic bulk systems, results with the more approximate files {{TAG|W000}}?.tmp are usually very similar to the results obtained using {{TAG|WFULL000}}?.tmp, however, for molecules and atoms as well as surfaces it is strictly required to use the full screened Coulomb kernel <math>W</math>.
{{TAG|SYSTEM}}   = Si
{{TAG|ISMEAR}}    = 0
{{TAG|SIGMA}}    = 0.05
{{TAG|NBANDS}}    = 16   
{{TAG|ALGO}}      = TDHF
{{TAG|IBSE}}      = 0
{{TAG|NBANDSO}}  = 4      ! number of occupied bands
{{TAG|NBANDSV}}   = 8      ! number of unoccupied bands
{{TAG|LHARTREE}}  = .TRUE.
{{TAG|LADDER}}   = .TRUE.
{{TAG|LFXC}}     = .FALSE. ! local xc kernel is disabled in mBSE
{{TAG|LMODELHF}} = .TRUE.
{{TAG|AEXX}}     = 0.083
{{TAG|HFSCREEN}}  = 1.22


In both cases, {{TAG|ALGO}}=''TDHF'' and {{TAG|ALGO}}=''BSE'', the dielectric function, as well as the calculated pair-excitation energies can be found in
== Calculations beyond Tamm-Dancoff approximation ==
the file {{TAG|vasprun.xml}}.
The TDHF and BSE calculations beyond the Tamm-Dancoff approximation (TDA){{cite|sander:prb:15}} can be performed by setting the {{TAG|ANTIRES}} = 2 in the {{TAG|INCAR}} file


== Calculations beyond Tamm Dancoff (TDA) approximation ==
{{TAG|SYSTEM}}      = Si
The VASP BSE code can perform calculations beyond the TDA <ref name="sander2015"/>, by setting the
{{TAG|NBANDS}}      = same as in GW calculation
{{TAG|ANTIRES}} =2 in the {{TAG|INCAR}} file e.g.
{{TAG|ISMEAR}}      = 0
{{TAG|SIGMA}}        = 0.05
{{TAG|ALGO}}        = BSE
{{TAG|ANTIRES}}     = 2     ! beyond Tamm-Dancoff
{{TAG|LORBITALREAL}} = .TRUE.  
{{TAG|NBANDSO}}      = 4
{{TAG|NBANDSV}}      = 8


{{TAGBL|System}} = Si
The flag {{TAG|LORBITALREAL}} = .TRUE. forces VASP to make the orbitals <math> \phi({\bf r}) </math> real valued at the Gamma point as well as k-points at the edges of the Brillouin zone. This can improve the performance of BSE/TDHF calculations but it should be used consistently with the ground-state calculation.
{{TAGBL|NBANDS}} = same as in GW calculation
{{TAGBL|ISMEAR}} = 0 ; {{TAGBL|SIGMA}} = 0.05
{{TAGBL|ALGO}} = BSE
{{TAGBL|ANTIRES}} = 2
{{TAGBL|LORBITALREAL}} = .TRUE.
{{TAGBL|NBANDSO}} = 4 ; {{TAGBL|NBANDSV}} = 8


Of course this also works for TDHF calculations. Furthermore, it is recommended to
== Calculations at finite wavevectors ==
perform all preceding calculations using the flag {{TAG|LORBITALREAL}} =''.TRUE.''. This forces VASP
VASP can also calculate the dielectric function at a <math>{\bf q}</math>-vector compatible with the k-point grid (finite-momentum excitons).  
to make the orbitals <math> \phi({\bf r}) </math> real valued at the Gamma point as well as k-points
at the edge of the Brillouin zone.


== Calculations at finite wave vectors ==
{{TAG|SYSTEM}}      = Si
For {{TAG|ANTIRES}} =2, VASP can also calculate the dielectric function at a q-vector compatible
{{TAG|NBANDS}}      = same as in GW calculation
with the k-point grid (finite momentum excitons).  
{{TAG|ISMEAR}}      = 0
{{TAG|SIGMA}}        = 0.05
{{TAG|ALGO}}        = BSE 
{{TAG|ANTIRES}}     = 2  
{{TAG|KPOINT_BSE}}  = 3 -1 0 0  ! q-point index,  three integers
{{TAG|LORBITALREAL}} = .TRUE.
{{TAG|NBANDSO}}      = 4
{{TAG|NBANDSV}}      = 8


{{TAGBL|System}} = Si
The tag {{TAG|KPOINT_BSE}} sets the <math>{\bf q}</math>-point and the shift at which the dielectric function is calculated. The first integer specifies the index of the <math>{\bf q}</math>-point and the other three values shift the provided <math>{\bf q}</math>-point by an arbitrary reciprocal vector <math> \bf G</math>The reciprocal lattice vector is supplied by three integer values <math> n_i</math> with <math> {\bf G}= n_1 {\bf G}_1+n_2 {\bf G}_2+n_3 {\bf G}_3</math>. This feature is only supported as of VASP.6 (in VASP.5 the feature can be enabled, but the results are erroneous).
{{TAGBL|NBANDS}} = same as in GW calculation
{{TAGBL|ISMEAR}} = 0 ; {{TAGBL|SIGMA}} = 0.05
  {{TAGBL|ALGO}} = BSE 
{{TAGBL|ANTIRES}} = 2
{{TAGBL|KPOINT_BSE}} = 3 -1 0 0 # k-point index, three integers
{{TAGBL|LORBITALREAL}} = .TRUE.
{{TAGBL|NBANDSO}} = 4 ; {{TAGBL|NBANDSV}} = 8


In the {{TAG|KPOINT_BSE}} line, four integer values must be supplied. The first one specifies the index of the k-point
== Consistency tests ==
at which the polarizability is supposed to be calculated. The other three
In order to verify the results obtained in the BSE calculation, one can perform a number of consistency tests.
values allow to shift the supplied k-point by an arbitrary  reciprocal vector <math> \bf G</math>. The reciprocal lattice vector
is supplied by three integer values  <math> n_i</math> with <math> {\bf G}= n_1 {\bf G}_1+n_2 {\bf G}_2+n_3 {\bf G}_3</math>.
This feature is only supported in vasp.6 (in vasp.5 the feature can be selected, but the results are erroneous).


== Always double check ==
=== First test: IP dielectric function ===
There are many ways to double check the BSE code, and here we highlight some possible cross checks.
The BSE code can be used to reproduce the independent particle spectrum if the RPA and the ladder diagrams are switched off
First the BSE code can be executed to reproduce the independent particle spectrum by adding the lines


  {{TAGBL|LADDER}} = .FALSE. ; {{TAGBL|LHARTREE}} = .FALSE.
  {{TAG|LADDER}}   = .FALSE.  
  {{TAG|LHARTREE}} = .FALSE.


This should yield exactly the same dielectric function as the preceding calculation using the {{TAG| LOPTICS}} = .TRUE.
This should yield exactly the same dielectric function as the preceding calculation with {{TAG| LOPTICS}} = .TRUE. We recommend to set the complex shift manually in the BSE as well as the preceding optics calculations, e.g. {{TAG | CSHIFT}} = 0.4. The dielectric functions produced in these calculations should be identical.
We recommend to set the complex shift manually in the BSE and preceding optics calculations e.g. {{TAG | CSHIFT}} = 0.4,
to obtain exactly the same results. This should yield absolutely identical results.


Second, one can use the RPA/GW routines to compare the dielectric function at the level of the RPA. In the
=== Second test: RPA dielectric function ===
BSE calculation simply add
The RPA/''GW'' dielectric function can be used to verify the correctness of the RPA dielectric function calculated via the BSE algorithm.  The RPA dielectric function in the BSE code can be calculated by switching off the ladder diagrams while keeping the RPA terms, i.e., the BSE calculation should be performed with the following tags


  {{TAGBL|ANTIRES}} = 2
  {{TAG|ANTIRES}}   = 2
  {{TAGBL|LADDER}} = .FALSE. ; {{TAGBL|LHARTREE}} = .TRUE.
  {{TAG|LHARTREE}} = .TRUE.
  {{TAGBL|CSHIFT}} = 0.4
  {{TAG|LADDER}}   = .FALSE.
  {{TAG|CSHIFT}}   = 0.4


and run the BSE calculations. The exactly same dielectric function can be obtained from the GW code
The same dielectric function should be obtained via the ''GW'' code by setting these flags


  {{TAGBL|ALGO}} = CHI ; {{TAGBL|NOMEGA}} = 200
  {{TAG|ALGO}}     = CHI  
  {{TAGBL|CSHIFT}} = 0.4
{{TAG|NOMEGA}}   = 200
  {{TAG|CSHIFT}}   = 0.4


Just make sure that a large {{TAG|CSHIFT}} is selected (the GW code calculates the polarizability only at few
Make sure that a large {{TAG|CSHIFT}} is selected as the ''GW'' code calculates the polarizability at very few frequency points. Note that the ''GW'' code does not use the TDA, so {{TAG|ANTIRES}} = 2 is required for the TDHF/BSE calculation. In our experience, the agreement can be made practically perfect provided sufficient frequency points are used and all available occupied and virtual orbitals are included in the BSE step.
frequency points). Note that the GW code does not use the Tamm-Dancoff approximation.
In our experience the agreement can be made practically perfect (if sufficient frequency points are used,
and if all occupied and virtual orbitals are included in the BSE calculation).


Furthermore, the TDHF/ BSE code calculates the correlation energy via the plasmon equation.
=== Third test: RPA correlation energy ===
This can be compared with the RPA contributions to the correlation energies for each q-point (see {{TAG|OUTCAR}} from
The BSE code can be used to calculate the correlation energy via the plasmon equation. This correlation energy can be compared with the [[ACFDT/RPA calculations|RPA contributions]] to the correlation energies for each <math>{\bf q}</math>-point, which can be found in the {{FILE|OUTCAR}} file of the ACFDT/RPA calculation performed with {{TAG|ALGO}} = RPA:
{{TAG|ALGO}} = ''RPA''):


  q-point correlation energy      -0.232563      0.000000
  q-point correlation energy      -0.232563      0.000000
Line 122: Line 148:
  q-point correlation energy      -0.176976      0.000000
  q-point correlation energy      -0.176976      0.000000


For instance, if the second k-point is selected in the BSE calculations
For instance, if the BSE calculation is performed at the second <math>{\bf q}</math>-point  


  {{TAGBL|ANTIRES}} = 2
  {{TAG|ANTIRES}}   = 2
  {{TAGBL|LADDER}} = .FALSE. ; {{TAGBL|LHARTREE}} = .TRUE.
  {{TAG|LADDER}}     = .FALSE.
  {{TAGBL|KPOINT_BSE}} = 2 0 0 0
  {{TAG|LHARTREE}}   = .TRUE.
  {{TAG|KPOINT_BSE}} = 2 0 0 0


exactly the same correlation energy should be found in the {{TAG|OUTCAR}} file of the BSE calculation:
the same correlation energy should be found in the corresponding {{FILE|OUTCAR}} file:


  plasmon correlation energy        -0.5716670828
  plasmon correlation energy        -0.5716670828


(for exact compatability {{TAG | ENCUT}} and {{TAG | ENCUTGW}} should be set to the same
For exact compatibility, {{TAG|ENCUT}} and {{TAG|ENCUTGW}} should be set to the same values in all calculations, while the head and wings of the dielectric matrix should not be included in the ACFDT/RPA calculations, i.e., remove the {{FILE|WAVEDER}} file prior to the ACFDT/RPA calculation. In the BSE/RPA calculation removing the {{FILE|WAVEDER}} file is not required.  Furthermore, {{TAG|NBANDS}} in the ACFDT/RPA calculation must be identical to the number of included bands {{TAG|NBANDSO}} plus {{TAG|NBANDSV}} in the BSE/RPA, so that the same number of excitation pairs are included in both calculations. Also, the {{TAG|OMEGAMAX}} tag in the BSE calculation should not be set.
values in the calculations and the head and wings should not be included in the RPA calculations, e.g.
rm {{TAG|WAVEDER}} prior to the RPA calculations).


== Common issues ==
== Common issues ==
If the dielectric matrix contains only zeros in the {{TAG|vasprun.xml}} file, the {{TAG|WAVEDER}} file was not read or is incompatible to the {{TAG|WAVEDER}} file. This requires a recalculation of the the {{TAG|WAVEDER}} file. This can be achieved even after GW calculations using the following intermediate step:
If the dielectric matrix contains only zeros in the {{FILE|vasprun.xml}} file, the {{FILE|WAVEDER}} file was not read or is incompatible to the {{FILE|WAVEDER}} file. This requires a recalculation of the {{FILE|WAVEDER}} file. This can be achieved even after ''GW'' calculations using the following intermediate step:


  {{TAGBL|ALGO}} = Nothing
  {{TAG|ALGO}}     = Nothing
  {{TAGBL|LOPTICS}} = .TRUE. ; {{TAGBL|LPEAD}} = .TRUE.
  {{TAG|LOPTICS}}   = .TRUE.
{{TAG|LPEAD}}     = .TRUE.


The flag {{TAG|LPEAD}}=''.TRUE.'' is strictly required and enforces a "numerical" differentiation of the orbitals with respect to <math>k</math>. Calculating the derivatives of the orbitals with respect to <math>k</math> analytically is not possible at this point, since the Hamiltonian that was used to determine the orbitals is unknown (to VASP) at this point.
The flag {{TAG|LPEAD}} = .TRUE. is strictly required and enforces a "numerical" differentiation of the orbitals with respect to <math>k</math>. Calculating the derivatives of the orbitals with respect to <math>k</math> analytically is not possible at this point, since the Hamiltonian that was used to determine the orbitals is unknown to VASP.


 
== Related tags and articles ==
 
 
== Related Tags and Sections ==
{{TAG|ALGO}},
{{TAG|ALGO}},
{{TAG|LOPTICS}},
{{TAG|LOPTICS}},
{{TAG|LPEAD}},
{{TAG|LHFCALC}},
{{TAG|LHFCALC}},
{{TAG|LRPA}},
{{TAG|LRPA}},
Line 155: Line 179:
{{TAG|LHARTREE}},
{{TAG|LHARTREE}},
{{TAG|NBANDSV}},
{{TAG|NBANDSV}},
{{TAG|NBANDSO}}
{{TAG|NBANDSO}},
 
{{TAG|OMEGAMAX}},
 
{{TAG|LFXC}},
{{sc|BSE|Examples|Examples that use this tag}}
{{TAG|ANTIRES}},
{{TAG|NBSEEIG}},
{{FILE|BSEFATBAND}}


== References ==
== References ==
<references>
<references/>
<ref name="albrecht1998">[http://journals.aps.org/prl/abstract/10.1103/PhysRevLett.80.4510 S. Albrecht, L. Reining, R. Del Sole, and G. Onida, Phys. Rev. Lett. 80, 4510 (1998).]</ref>
<ref name="rohlfing1998">[http://journals.aps.org/prl/abstract/10.1103/PhysRevLett.81.2312 M. Rohlfing, S.G. Louie, Phys. Rev. Lett. 81, 2312 (1998).]</ref>
 
<ref name="sander2015">[https://doi.org/10.1103/PhysRevB.92.045209 S. Tobias, E. Maggio, and G. Kresse, Phys. Rev. B 92.4 (2015).]</ref>
</references>
 
 


----
----
[[The_VASP_Manual|Contents]]
[[Category:Many-body perturbation theory]][[Category:Bethe-Salpeter equations]][[Category:Howto]]
 
[[Category:INCAR]][[Category:BSE]][[Category:Howto]]

Latest revision as of 17:34, 7 February 2024

VASP offers a powerful module for solving the Bethe-Salpeter (BSE) equation[1][2]. The BSE can be used for obtaining the frequency-dependent dielectric function with the excitonic effects and can be based on the ground-state electronic structure in the DFT, hybrid-functional or GW approximations.

Solving Bethe-Salpeter equation

To take into account the excitonic effects or the electron-hole interaction, one has to use approximations beyond the independent-particle (IP) and the random-phase approximations (RPA). In VASP, it is done via the algorithm selected by ALGO = BSE. These essentially solves the same equations (Casida/Bethe-Salpeter) but differ in the way the screening of the Coulomb potential is treated. The TDHF approach uses the exact-correlation kernel , whereas BSE requires the from a preceding GW calculation. Thus, in order to perform TDHF or BSE calculations, one has to provide the ground-state orbitals (WAVECAR) and the derivatives of the orbitals with respect to (WAVEDER). In addition, the BSE calculation requires files storing the screened Coulomb kernel produced in a GW calculation, i.e., Wxxxx.tmp.

In summary, both TDHF and BSE approaches require a preceding ground-state calculation, however, the TDHF does not need the preceding GW and can be performed with the DFT or hybrid-functional orbitals and energies.

Bethe-Salpeter equation calculation

The BSE calculations require a preceding GW step to determine the screened Coulomb kernel . The details on GW calculations can be found in the practical guide to GW calculations. Here, we note that during the GW calculation, VASP writes this kernel into the following files

W0001.tmp, W0002.tmp, ..., W{NKPTS}.tmp

and

WFULL0001.tmp, WFULL0002.tmp, ..., WFULL{NKPTS}.tmp.

The files Wxxxx.tmp store only the diagonal terms of the kernel and are fairly small, whereas the files WFULLxxxx.tmp store the full matrix. It is important to make sure in the GW step that the flag LWAVE = .TRUE. is set, so that the WAVECAR stores the one-electron GW energies and the one-electron orbitals, if the GW calculation is self-consistent.

For the self-consistent GW calculations the following flags should be added

LOPTICS   = .TRUE. 
LPEAD     = .TRUE.

in order to update the WAVEDER using finite differences (LPEAD = .TRUE.). The type of GW calculation is selected with the ALGO tag, which is discussed in great detail in the practical guide to GW calculations.

Once the GW step is completed, the BSE calculation can be performed using the following setup

SYSTEM    = Si
NBANDS    = same as in GW calculation
ISMEAR    = 0
SIGMA     = 0.05
ALGO      = BSE
NBANDSO   = 4       ! determines how many occupied bands are used
NBANDSV   = 8       ! determines how many unoccupied (virtual) bands are used
OMEGAMAX  = desired_maximum_excitation_energy 

Considering that quasiparticle energies in GW converge very slowly with the number of unoccupied bands and require large NBANDS, the number of bands included in the BSE calculation should be restricted explicitly by setting the occupied and unoccupied bands (NBANDSO and NBANDSV) included in the BSE Hamiltonian.

VASP tries to use sensible defaults, but it is highly recommended to check the OUTCAR file and make sure that the right bands are included. The tag OMEGAMAX specifies the maximum excitation energy of included electron-hole pairs and the pairs with the one-electron energy difference beyond this limit are not included in the BSE Hamiltonian. Hint: The convergence with respect to NBANDSV and OMEGAMAX should be thoroughly checked as the real part of the dielectric function, as well as the correlation energy, is usually very sensitive to these values, whereas the imaginary part of the dielectric function converges quickly.

At the beginning of the BSE calculation, VASP will try to read the WFULLxxxx.tmp files and if these files are not found, VASP will read the Wxxxx.tmp files. For small isotropic bulk systems, the diagonal approximation of the dielectric screening may be sufficient and yields results very similar to the calculation with the full dielectric tensor WFULLxxxx.tmp. Nevertheless, for molecules and atoms as well as surfaces, the full-screened Coulomb kernel is strictly required.

Both TDHF and BSE approaches write the calculated frequency-dependent dielectric function as well as the excitonic energies in the vasprun.xml file.

Model BSE (mBSE)

BSE calculations can be performed using a model dielectric function[3][4]. In this approach the calculation of the screened Coulomb potential is not required. Instead, the model dielectric function can be used to describe the screening of the Coulomb potential by setting the tag LMODELHF with parameters AEXX and HFSCREEN.

Model BSE calculation can be performed the following steps:

  1. ground-state calculation
  2. GW calculation (optional in model BSE calculation)
  3. optical absorption calculation via model BSE

For example, an optical absorption calculation of bulk Si can be performed using a model dielectric function as described in Ref. [4].

SYSTEM    = Si
ISMEAR    = 0 
SIGMA     = 0.05
NBANDS    = 16      ! or any larger desired value
ALGO      = D       ! Damped algorithm often required for HF type calculations, ALGO = Normal might work as well
LHFCALC   = .TRUE. 
LMODELHF  = .TRUE. 
AEXX      = 0.083
HFSCREEN  = 1.22
LOPTICS   = .TRUE.  ! can also be done in an additional intermediate step

In the second step, the dielectric function is evaluated by solving the Casida equation

SYSTEM    = Si
ISMEAR    = 0 
SIGMA     = 0.05
NBANDS    = 16     
ALGO      = TDHF
IBSE      = 0
NBANDSO   = 4       ! number of occupied bands
NBANDSV   = 8       ! number of unoccupied bands
LHARTREE  = .TRUE.
LADDER    = .TRUE.
LFXC      = .FALSE. ! local xc kernel is disabled in mBSE 
LMODELHF  = .TRUE. 
AEXX      = 0.083
HFSCREEN  = 1.22

Calculations beyond Tamm-Dancoff approximation

The TDHF and BSE calculations beyond the Tamm-Dancoff approximation (TDA)[5] can be performed by setting the ANTIRES = 2 in the INCAR file

SYSTEM       = Si
NBANDS       = same as in GW calculation
ISMEAR       = 0
SIGMA        = 0.05
ALGO         = BSE  
ANTIRES      = 2      ! beyond Tamm-Dancoff
LORBITALREAL = .TRUE. 
NBANDSO      = 4 
NBANDSV      = 8

The flag LORBITALREAL = .TRUE. forces VASP to make the orbitals real valued at the Gamma point as well as k-points at the edges of the Brillouin zone. This can improve the performance of BSE/TDHF calculations but it should be used consistently with the ground-state calculation.

Calculations at finite wavevectors

VASP can also calculate the dielectric function at a -vector compatible with the k-point grid (finite-momentum excitons).

SYSTEM       = Si
NBANDS       = same as in GW calculation
ISMEAR       = 0 
SIGMA        = 0.05
ALGO         = BSE  
ANTIRES      = 2 
KPOINT_BSE   = 3 -1 0 0  ! q-point index,  three integers
LORBITALREAL = .TRUE.
NBANDSO      = 4 
NBANDSV      = 8

The tag KPOINT_BSE sets the -point and the shift at which the dielectric function is calculated. The first integer specifies the index of the -point and the other three values shift the provided -point by an arbitrary reciprocal vector . The reciprocal lattice vector is supplied by three integer values with . This feature is only supported as of VASP.6 (in VASP.5 the feature can be enabled, but the results are erroneous).

Consistency tests

In order to verify the results obtained in the BSE calculation, one can perform a number of consistency tests.

First test: IP dielectric function

The BSE code can be used to reproduce the independent particle spectrum if the RPA and the ladder diagrams are switched off

LADDER   = .FALSE. 
LHARTREE = .FALSE.

This should yield exactly the same dielectric function as the preceding calculation with LOPTICS = .TRUE. We recommend to set the complex shift manually in the BSE as well as the preceding optics calculations, e.g. CSHIFT = 0.4. The dielectric functions produced in these calculations should be identical.

Second test: RPA dielectric function

The RPA/GW dielectric function can be used to verify the correctness of the RPA dielectric function calculated via the BSE algorithm. The RPA dielectric function in the BSE code can be calculated by switching off the ladder diagrams while keeping the RPA terms, i.e., the BSE calculation should be performed with the following tags

ANTIRES   = 2
LHARTREE  = .TRUE.
LADDER    = .FALSE.
CSHIFT    = 0.4

The same dielectric function should be obtained via the GW code by setting these flags

ALGO      = CHI 
NOMEGA    = 200
CSHIFT    = 0.4

Make sure that a large CSHIFT is selected as the GW code calculates the polarizability at very few frequency points. Note that the GW code does not use the TDA, so ANTIRES = 2 is required for the TDHF/BSE calculation. In our experience, the agreement can be made practically perfect provided sufficient frequency points are used and all available occupied and virtual orbitals are included in the BSE step.

Third test: RPA correlation energy

The BSE code can be used to calculate the correlation energy via the plasmon equation. This correlation energy can be compared with the RPA contributions to the correlation energies for each -point, which can be found in the OUTCAR file of the ACFDT/RPA calculation performed with ALGO = RPA:

q-point correlation energy      -0.232563      0.000000
q-point correlation energy      -0.571667      0.000000
q-point correlation energy      -0.176976      0.000000

For instance, if the BSE calculation is performed at the second -point

ANTIRES    = 2
LADDER     = .FALSE.
LHARTREE   = .TRUE.
KPOINT_BSE = 2 0 0 0

the same correlation energy should be found in the corresponding OUTCAR file:

plasmon correlation energy        -0.5716670828

For exact compatibility, ENCUT and ENCUTGW should be set to the same values in all calculations, while the head and wings of the dielectric matrix should not be included in the ACFDT/RPA calculations, i.e., remove the WAVEDER file prior to the ACFDT/RPA calculation. In the BSE/RPA calculation removing the WAVEDER file is not required. Furthermore, NBANDS in the ACFDT/RPA calculation must be identical to the number of included bands NBANDSO plus NBANDSV in the BSE/RPA, so that the same number of excitation pairs are included in both calculations. Also, the OMEGAMAX tag in the BSE calculation should not be set.

Common issues

If the dielectric matrix contains only zeros in the vasprun.xml file, the WAVEDER file was not read or is incompatible to the WAVEDER file. This requires a recalculation of the WAVEDER file. This can be achieved even after GW calculations using the following intermediate step:

ALGO      = Nothing
LOPTICS   = .TRUE.
LPEAD     = .TRUE.

The flag LPEAD = .TRUE. is strictly required and enforces a "numerical" differentiation of the orbitals with respect to . Calculating the derivatives of the orbitals with respect to analytically is not possible at this point, since the Hamiltonian that was used to determine the orbitals is unknown to VASP.

Related tags and articles

ALGO, LOPTICS, LPEAD, LHFCALC, LRPA, LADDER, LHARTREE, NBANDSV, NBANDSO, OMEGAMAX, LFXC, ANTIRES, NBSEEIG, BSEFATBAND

References