FERWE: Difference between revisions
No edit summary |
|||
(One intermediate revision by the same user not shown) | |||
Line 8: | Line 8: | ||
In the case of spin-polarized calculations ({{TAG|ISPIN}}=2), {{TAG|FERWE}} sets the occupancies of the states in the up-spin channel. Specify the occupancies of the states in the down-spin channel by means of the {{TAG|FERDO}} tag. | In the case of spin-polarized calculations ({{TAG|ISPIN}}=2), {{TAG|FERWE}} sets the occupancies of the states in the up-spin channel. Specify the occupancies of the states in the down-spin channel by means of the {{TAG|FERDO}} tag. | ||
{{NB|mind|If the calculation stops with an error message when reading {{TAG|FERWE}}, then this may be due to an automatic increase of the number of bands {{TAG|NBANDS}} in parallel calculation (the new value of {{TAG|NBANDS}} is indicated in the corresponding warning message). If this is the case, then the number of occupancies provided to {{TAG|FERWE}} should be increased according to the new {{TAG|NBANDS}}.}} | {{NB|mind|If the calculation stops with an error message when reading {{TAG|FERWE}}, then this may be due to an automatic increase of the number of bands {{TAG|NBANDS}} in parallel calculation (the new value of {{TAG|NBANDS}} is indicated in the corresponding warning message). If this is the case, then the number of occupancies provided to {{TAG|FERWE}} should be increased according to the new {{TAG|NBANDS}}.}} | ||
Line 16: | Line 15: | ||
{{sc|FERWE|Examples|Examples that use this tag}} | {{sc|FERWE|Examples|Examples that use this tag}} | ||
[[Category:INCAR tag]][[Category:Electronic | [[Category:INCAR tag]][[Category:Electronic occupancy]][[Category:Density of states]] |
Latest revision as of 10:10, 17 October 2024
FERWE = [real array]
Description: FERWE sets the occupancies of the states for ISMEAR=-2.
To set the occupancies, specify
FERWE = f(1) f(2) f(3) ... f(NBANDS×Nk)
The occupancies must be specified for all bands and k points. The band index runs fastest. The occupancies must be between 0 and 1.
In the case of spin-polarized calculations (ISPIN=2), FERWE sets the occupancies of the states in the up-spin channel. Specify the occupancies of the states in the down-spin channel by means of the FERDO tag.
Mind: If the calculation stops with an error message when reading FERWE, then this may be due to an automatic increase of the number of bands NBANDS in parallel calculation (the new value of NBANDS is indicated in the corresponding warning message). If this is the case, then the number of occupancies provided to FERWE should be increased according to the new NBANDS. |