(7 intermediate revisions by 2 users not shown) |
Line 25: |
Line 25: |
| *{{TAG|VDW_A2}}=[real] | | *{{TAG|VDW_A2}}=[real] |
|
| |
|
| {{NB|mind|The default values for the damping function parameters are available for several ({{TAG|GGA}} (PBE, RPBE, revPBE and PBEsol), {{TAG|METAGGA}} (TPSS, M06L and SCAN) and [[list_of_hybrid_functionals|hybrid]] () functionals. If another functional is used, the user has to define these parameters via the corresponding tags in the {{TAG|INCAR}} file. The up-to-date list of parametrized DFT functionals with recommended values of damping function parameters can be found on the webpage https://www.chemiebn.uni-bonn.de/pctc/mulliken-center/software/dft-d3/dft-d3.}} | | {{NB|mind| |
| {{NB|mind|The DFT-D3 method has been implemented in VASP by Jonas Moellmann based on the dftd3 program written by Stefan Grimme, Stephan Ehrlich and Helge Krieg. If you make use of the DFT-D3 method, please cite reference {{cite|grimme:jcp:10}}. When using DFT-D3(BJ) references {{cite|grimme:jcp:10}} and {{cite|grimme:jcc:11}} should also be cited.}}
| | *The default values for the damping function parameters are available for several {{TAG|GGA}} (PBE, RPBE, revPBE and PBEsol), {{TAG|METAGGA}} (TPSS, M06L and SCAN) and [[list_of_hybrid_functionals|hybrid]] (B3LYP and PBEh/PBE0) functionals, as well as [[list_of_hybrid_functionals|Hartree-Fock]]. If another functional is used, the user has to define these parameters via the corresponding tags in the {{TAG|INCAR}} file. The up-to-date list of parametrized DFT functionals with recommended values of damping function parameters can be found on the webpage https://www.chemie.uni-bonn.de/grimme/de/software/dft-d3/ and follow the link "List of parametrized functionals"). |
| | *The DFT-D3 method has been implemented in VASP by Jonas Moellmann based on the dftd3 program written by Stefan Grimme, Stephan Ehrlich and Helge Krieg. If you make use of the DFT-D3 method, please cite reference {{cite|grimme:jcp:10}}. When using DFT-D3(BJ) references {{cite|grimme:jcp:10}} and {{cite|grimme:jcc:11}} should also be cited. Also carefully check the more extensive list of references found on https://www.chemie.uni-bonn.de/grimme/de/software/dft-d3/.}} |
|
| |
|
| == Related tags and articles == | | == Related tags and articles == |
Line 37: |
Line 38: |
| {{TAG|IVDW}}, | | {{TAG|IVDW}}, |
| {{TAG|DFT-D2}}, | | {{TAG|DFT-D2}}, |
| {{TAG|Tkatchenko-Scheffler method}},
| | [[DFT-D4]] |
| {{TAG|Tkatchenko-Scheffler method with iterative Hirshfeld partitioning}},
| |
| {{TAG|Self-consistent screening in Tkatchenko-Scheffler method}},
| |
| {{TAG|Many-body dispersion energy}},
| |
| {{TAG|dDsC dispersion correction}}
| |
|
| |
|
| == References == | | == References == |
Latest revision as of 13:14, 5 July 2024
In the DFT-D3 method of Grimme et al.[1], the following expression for the vdW-dispersion energy-correction term is used:
Unlike in the method DFT-D2, the dispersion coefficients are geometry-dependent as they are adjusted on the basis of the local geometry (coordination number) around atoms and . In the zero-damping variant of the DFT-D3 method (DFT-D3(zero)), the damping function reads:
where , the parameters , , and are fixed at values of 14, 16, 1, and 1, respectively, while and are adjustable parameters whose values depend on the choice of the exchange-correlation functional. The DFT-D3(zero) method is invoked by setting IVDW=11. Optionally, the following parameters can be user-defined (the given values are the default ones):
- VDW_RADIUS=50.2 : cutoff radius (in ) for pair interactions considered in the equation of
- VDW_CNRADIUS=20.0 : cutoff radius (in ) for the calculation of the coordination numbers
- VDW_S8=[real] : damping function parameter
- VDW_SR=[real] : damping function parameter
Alternatively, the Becke-Johnson (BJ) damping can be used in the DFT-D3 method[2]:
with and , , and being adjustable parameters.
This variant of DFT-D3 method (DFT-D3(BJ)) is invoked by setting IVDW=12. As before, the parameters VDW_RADIUS and VDW_CNRADIUS can be used to change the default values for the cutoff radii. The parameters of the damping function can be controlled using the following tags:
Mind:
- The default values for the damping function parameters are available for several GGA (PBE, RPBE, revPBE and PBEsol), METAGGA (TPSS, M06L and SCAN) and hybrid (B3LYP and PBEh/PBE0) functionals, as well as Hartree-Fock. If another functional is used, the user has to define these parameters via the corresponding tags in the INCAR file. The up-to-date list of parametrized DFT functionals with recommended values of damping function parameters can be found on the webpage https://www.chemie.uni-bonn.de/grimme/de/software/dft-d3/ and follow the link "List of parametrized functionals").
- The DFT-D3 method has been implemented in VASP by Jonas Moellmann based on the dftd3 program written by Stefan Grimme, Stephan Ehrlich and Helge Krieg. If you make use of the DFT-D3 method, please cite reference [1]. When using DFT-D3(BJ) references [1] and [2] should also be cited. Also carefully check the more extensive list of references found on https://www.chemie.uni-bonn.de/grimme/de/software/dft-d3/.
|
Related tags and articles
VDW_RADIUS,
VDW_CNRADIUS,
VDW_S8,
VDW_SR,
VDW_A1,
VDW_A2,
IVDW,
DFT-D2,
DFT-D4
References