MIXPRE: Difference between revisions
No edit summary |
|||
(One intermediate revision by one other user not shown) | |||
Line 30: | Line 30: | ||
---- | ---- | ||
[[Category:INCAR]][[Category:Electronic | [[Category:INCAR tag]][[Category:Electronic minimization]][[Category:Density mixing]] |
Revision as of 14:46, 8 April 2022
MIXPRE = 0 | 1 | 2 | 3
Default: MIXPRE = 1
Description: MIXPRE specifies the metric in the Broyden mixing scheme(IMIX=4).
- MIXPRE=0
- No preconditioning, metric=1
- MIXPRE=1
- "Inverse Kerker" metric with automatically determined BMIX (determined in such a way that the variation of the preconditioning weights covers a range of a factor 20)
- MIXPRE=2
- "Inverse Kerker" metric with automatically determined BMIX (determined in such a way that the variation of the preconditioning weights covers a range of a factor 200)
- MIXPRE=3 (implemented for test purposes; not recommended)
The preconditioning is done only on the total charge density (i.e. up+down component) and not on the magnetization charge density (i.e. up-down component). In our experience, the introduction of a metric always improves the convergence speed. The best choice is MIXPRE=1 (i.e. the default).
Related tags and articles
IMIX, INIMIX, MAXMIX, AMIX, BMIX, AMIX_MAG, BMIX_MAG, AMIN, WC